mirror of
https://github.com/SamyRai/turash.git
synced 2025-12-26 23:01:33 +00:00
Repository Structure:
- Move files from cluttered root directory into organized structure
- Create archive/ for archived data and scraper results
- Create bugulma/ for the complete application (frontend + backend)
- Create data/ for sample datasets and reference materials
- Create docs/ for comprehensive documentation structure
- Create scripts/ for utility scripts and API tools
Backend Implementation:
- Implement 3 missing backend endpoints identified in gap analysis:
* GET /api/v1/organizations/{id}/matching/direct - Direct symbiosis matches
* GET /api/v1/users/me/organizations - User organizations
* POST /api/v1/proposals/{id}/status - Update proposal status
- Add complete proposal domain model, repository, and service layers
- Create database migration for proposals table
- Fix CLI server command registration issue
API Documentation:
- Add comprehensive proposals.md API documentation
- Update README.md with Users and Proposals API sections
- Document all request/response formats, error codes, and business rules
Code Quality:
- Follow existing Go backend architecture patterns
- Add proper error handling and validation
- Match frontend expected response schemas
- Maintain clean separation of concerns (handler -> service -> repository)
35 lines
1.1 KiB
Go
35 lines
1.1 KiB
Go
package financial
|
|
|
|
// CO2CalculatorImpl implements CO2Calculator interface
|
|
type CO2CalculatorImpl struct {
|
|
config *Config
|
|
}
|
|
|
|
// NewCO2Calculator creates a new CO2 calculator
|
|
func NewCO2Calculator(config *Config) CO2Calculator {
|
|
return &CO2CalculatorImpl{config: config}
|
|
}
|
|
|
|
// CalculateCO2Reduction calculates annual CO₂ emissions avoided
|
|
func (cc *CO2CalculatorImpl) CalculateCO2Reduction(resourceType string, annualVolume float64) float64 {
|
|
// Handle negative volumes
|
|
if annualVolume <= 0 {
|
|
return 0.0
|
|
}
|
|
|
|
// Only calculate for energy-related resources
|
|
switch resourceType {
|
|
case "heat", "steam", "cooling":
|
|
// Assume volume is in MWh/year
|
|
return annualVolume * cc.config.GridEmissionFactor * cc.config.HeatEfficiency * cc.config.UtilizationRate
|
|
case "water":
|
|
// Water treatment energy: config.WaterTreatmentKwh kWh/m³
|
|
return annualVolume * (cc.config.WaterTreatmentKwh / 1000) * cc.config.GridEmissionFactor // Convert kWh to MWh
|
|
case "biowaste":
|
|
// Waste diversion avoided emissions: config.WasteDiversionCo2 t CO₂/tonne waste
|
|
return annualVolume * cc.config.WasteDiversionCo2
|
|
default:
|
|
return 0.0
|
|
}
|
|
}
|